Physiological Parameter Sensing with Wearable Devices and Non-Contact Doppler Radar

Date

2017-05

Contributor

Advisor

Instructor

Depositor

Speaker

Researcher

Consultant

Interviewer

Narrator

Transcriber

Annotator

Journal Title

Journal ISSN

Volume Title

Publisher

University of Hawaii at Manoa

Volume

Number/Issue

Starting Page

Ending Page

Alternative Title

Abstract

Vital sign measurement with wearable devices is an important need in the paradigm shift occurring with health care. The Internet of things (IoT) is a concept that will allow healthcare providers to keep up to date continuously on the health of their patients through accurate wearable sensors and non-contact sensing in their homes. In order to meet this growing need for robust sensors, there are currently many devices that sense physiological parameters through photo-plethysmography (PPG) and piezoelectric methods. These methods of sensing have their own inherent limitations which include low flexibility, inaccuracy at higher rates, and susceptibility to motion artifact. Elastomeric sensors are another material being explored because of it’s potential for higher flexibility than piezoelectric pressure sensors. A wearable elastomeric arm sensor, that was designed and tested on the upper arm of 3 subjects, showed capability of measuring respiratory and heart rate with a low voltage DC power source. In addition to wearable sensors, there is a need for non-contact sensing in home health monitoring. Previous research with Doppler radar physiological sensing has focused mostly on measuring respiratory rate and displacement accurately. Recent work with radar cross-section (RCS) measurements, have shown that it is possible to determine body position of a subject based on the RCS. A study was done to investigate the dynamic RCS of a human subject during varying respiration depth. Measurement with a retro-reflective infrared camera marker on the sternum of the subject was used as a reference and compared with a 2.4GHz continuous wave Doppler radar system. Results showed that the RCS of a subject facing the radar changed between deep and shallow breathing. A further study with 13 reference markers revealed that there were two main areas, sternum and abdomen, that contributed to the overall dynamic RCS. The implications of this study are important for accurately determining subject position, medical diagnosis, and unique identification with Doppler radar

Description

Keywords

Doppler radar, Wearable Devices, Vital Sign Sensing

Citation

Extent

Format

Geographic Location

Time Period

Related To

Related To (URI)

Table of Contents

Rights

Rights Holder

Local Contexts

Email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.