Assessing the Accuracy of an Environmental Monitoring System in the Ala Wai Harbor
Loading...
Date
Authors
Contributor
Advisor
Editor
Performer
Department
Instructor
Depositor
Speaker
Researcher
Consultant
Interviewer
Interviewee
Narrator
Transcriber
Annotator
Journal Title
Journal ISSN
Volume Title
Publisher
Journal Name
Volume
Number/Issue
Starting Page
Ending Page
Alternative Title
Abstract
The ZAPS Technologies LiquID station is an innovative instrument that uses light to | monitor the overall quality of water in real time through a process called Zero Angle Photon Spectroscopy (ZAPS). The primary objective of this study was to evaluate the ZAPS LiquID instrument to see if the real-time concentration data that it provides correlate with values obtained by manual discrete sampling and traditional methods of analysis. For this study, we compared chlorophyll-a, nutrients (NO3 and NO2), total suspended solids (TSS) concentration and turbidity. For those parameters measured by the PacIOOS nearshore sensor at Hawai‘i Yacht Club, O‘ahu, data were taken for an additional comparison. For chlorophyll-a and TSS, the LiquID sensor gave similar data to those analyzed in the laboratory while for nutrients, a dissolved constituent, the LiquID overestimated values. Chlorophyll-a display considerable variability but the data from the various methods all fall within in the same range with 14% of LiquID data showing extremely similar results to data examined by the lab. Laboratory TSS values yield similar results to those data from the LiquID if sample water is filtered through cellulose acetate membranes and dried at a temperature above the boiling point of water. LiquID sensor data for NO3 and NO2 was larger by about a factor of four and although absolute values do not match, a decent correlation was observed given by an R2 value of 0.33. Turbidity values, although measured in different units that are not directly comparable, show comparable trends with an R2 value of 0.46 for data generated by the PacIOOS and the LiquID. Higher lab values for TSS and chlorophyll-a may be attributed to the long length and fouling of the intake line; however, for dissolved constituents, a sensor calibration may be the problem.
Description
Keywords
Subject Headings
Citation
DOI
Extent
59 pages
Format
Type
Thesis
Text
Text
Geographic Location
Time Period
Related To
Related To (URI)
Table of Contents
Rights
All UHM dissertations and theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission from the copyright owner.
Rights Holder
Catalog Record
Local Contexts
Collections
Endorsement
Review
Supplemented By
Referenced By
Email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.