Report on uncontrolled flow event as per conditions #13 and #26, ATC no. A-833-795, attachment II, wellfield

dc.contributor.author Puna Geothermal Venture
dc.date.accessioned 2012-08-16T19:47:30Z
dc.date.accessioned 2012-08-16T20:55:40Z
dc.date.available 2012-08-16T19:47:30Z
dc.date.available 2012-08-16T20:55:40Z
dc.date.issued 1991-06-17
dc.description Includes a cover letter.
dc.description.abstract This report covers the following five items: probable cause of the blowout, actions that have or will be taken, estimated time before the well is controlled, analysis of air quality impact from unabated emissions, and air quality monitoring plan.
dc.format.extent 19 pages
dc.identifier.citation Puna Geothermal Venture. 1991. Report on uncontrolled flow event as per conditions #13 and #26, ATC no. A-833-795, attachment II, Wellfield. Pahoa (HI): Puna Geothermal Venture.
dc.identifier.uri http://hdl.handle.net/10524/23409
dc.language.iso en-US
dc.publisher Puna Geothermal Venture
dc.subject KS-8
dc.subject KS-8 unplanned venting
dc.subject well blowout
dc.subject venting
dc.subject Puna Geothermal Venture
dc.subject Kapoho
dc.subject Kilauea
dc.subject Puna
dc.subject Hawaii
dc.subject Kilauea Lower East Rift Zone
dc.subject Kilauea East Rift Zone
dc.title Report on uncontrolled flow event as per conditions #13 and #26, ATC no. A-833-795, attachment II, wellfield