Noninvasive Electromagnetic Sensors for Continuous Monitoring of Human Vital Signs and Assessment of Lung Fluid Content
Loading...
Date
Authors
Contributor
Advisor
Department
Instructor
Depositor
Speaker
Researcher
Consultant
Interviewer
Interviewee
Narrator
Transcriber
Annotator
Journal Title
Journal ISSN
Volume Title
Publisher
University of Hawaii at Manoa
Volume
Number/Issue
Starting Page
Ending Page
Alternative Title
Abstract
Early detection and continuous assessment of lung fluid content or abnormal fluid buildup in the lungs, is the foundation to the management and treatment of life threatening diseases such as heart failure (HF), and other cardiopulmonary related illnesses. However, available modalities are either invasive and/or not suitable for continuous monitoring. The Cardiopulmonary Stethoscope (CPS) system, aims to address this need. The CPS system is a noninvasive, portable, low-cost device, capable of monitoring vital signs (VS) such as heart rate (HR), respiratory rate (RR), and most importantly, detect changes in lung fluid content. This study is related to the development of the system and its use in clinical trials. Contributions of this dissertation included the following: (1) A textile based sensor for remote monitoring and wearable applications was developed and clinically validated for HR and RR measurements on healthy patients. (2) Specific Absorption Rate (SAR) measurements were conducted eith the DASY4 system using safety compliance guidelines set forth by the FCC. With 32 mW input power, the measured SAR was 0.4 W/kg which is only 1/4th of the FCC limit of 1.6 W/kg for 1g avg. (3) HR and RR measurements were clinically validated on seven healthy participants at rest and during exercise. Measured differences between the CPS device and standard hemodynamic devices were all within the limits of agreement, which were calculated using Bland-Altman analysis. (4) In collaboration with the Queen's Medical Center, sensitivity to changes in lung fluid content was also clinically validated with thirteen heart failure (HF) and eight hemodialysis (HD) patients. Polynomial regression fit of the overall changes in phase was generally in good agreement with the trend of the pulmonary arterial pressure measurements from the HF patients and fluid removed during hemodialysis treatment. HR and RR measurements also showed strong correlation (Pearson — Heart rate (HF): r = 0.79, p<0.05, (HD): r = 0.85, p<0.05; Respiratory rate (HF): r = 0.71, p<0.05, (HD): r = 0.42, p<0.05). (5) Simulation and experimental results have shown that sensor placement need to be considered in evaluating tradeoffs between monitoring vital signs and enhancing sensitivity to changes in lung fluid content.
Description
Keywords
Citation
DOI
Extent
Format
Geographic Location
Time Period
Related To
Theses for the degree of Doctor of Philosophy (University of Hawaii at Manoa). Electrical Engineering
Related To (URI)
Table of Contents
Rights
Rights Holder
Catalog Record
Local Contexts
Collections
Email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.
