Isokinetic bench press as a criterion measure of upper body power in NCAA Division I college football player starters and non-starters

Date

2003-08

Contributor

Instructor

Depositor

Speaker

Researcher

Consultant

Interviewer

Narrator

Transcriber

Annotator

Journal Title

Journal ISSN

Volume Title

Publisher

University of Hawaii at Manoa

Volume

Number/Issue

Starting Page

Ending Page

Alternative Title

Abstract

The purpose of this study was to investigate whether the isokinetic bench press could discriminate football-playing ability and to correlate the isokinetic bench press with other commonly used football upper and lower body power tests. National Collegiate Athletic Association (NCAA) Division I collegiate football players aged 18-26 years were divided into two groups by player ability: starters (Group 2) and non-starters (Group 1). On separate days, subjects performed the vertical jump, 40-yard dash, one-repetition maximum (RM) bench press and isokinetic bench press at 60, 180 and 300°/s. Pearson Correlation Coefficient analysis revealed significant correlations among all measures in the present study (height, weight, isokinetic peak force at 60°/s, 180°/s and 300°/s, vertical jump, 1-RM bench press and 40-yard dash). Height and weight negatively correlated with all measures, except the 40-yard dash, indicating that taller and/or heavier football players produced higher (slower) 40-yard dash times. Three 1 x 2 ANOVA's (p<0.05) were used to compare 40-yard dash times, vertical jump, and 1-RM bench press between starters and non-starters, respectively. Results indicated that 40-yard dash times of starters were significantly faster than non-starters, and no significant differences in vertical jump values and 1-RM bench press torque between starters and non-starters. Four x 2 ANOVA with repeated measures (p<0.05) analysis indicated that starters and non-starters produced significantly higher 1-RM bench press torque values than isokinetic bench press peak torque values at 60, 180, and 300°/s; higher isokinetic bench press peak torque values at 60°s/ than at 180 and 300°/s; and no significant difference between isokinetic bench press peak torque values at 180 and 300°/s. Three x 2 ANOVA with repeated measures (p<0.05) analysis indicated that football starters produced significantly higher isokinetic bench press peak torque values at 60°/s than nonstarters. Conclusion: isokinetic bench press can be used as an upper body power test to discriminate between starters and non-starters.

Description

Keywords

Citation

Extent

viii, 48 pages

Format

Geographic Location

Time Period

Related To

Theses for the degree of Master of Science (University of Hawaii at Manoa). Kinesiology and Leisure Science; no. 3803

Related To (URI)

Table of Contents

Rights

All UHM dissertations and theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission from the copyright owner.

Rights Holder

Local Contexts

Email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.