First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990

dc.contributor.author Measurement Technologies en_US
dc.date.accessioned 2015-07-06T23:42:03Z en_US
dc.date.accessioned 2015-07-07T22:24:34Z
dc.date.available 2015-07-06T23:42:03Z en_US
dc.date.available 2015-07-07T22:24:34Z
dc.date.issued 1990 en_US
dc.description.abstract "The aerometric analyzer audit results were satisfactory. The sulfur dioxide (502) and hydrogen sulfide (H2S) analyzers meet the slope and intercept criteria. Although the H2S analyzer passed the slope and intercept criteria, the analyzer exhibited a large negative differential on the lower concentration range of the analyzer. The analyzer linerizer was adjusted and a post audit was performed. The reaudit showed satisfactory results and the low range showed a smaller negative differential. The meteorological equipment audit results were satisfactory. The particulate sampler audit results were satisfactory. All operational procedures followed at the monitoring sites were consistent with EPA guidelines, and all instrument/analyzer calibrations were done in a proper manner. All documentation was found to be complete, concise, and up to date." en_US
dc.description.sponsorship True Geothermal Energy Company en_US
dc.format.extent 35 pages en_US
dc.identifier.citation Measurement Technologies. 1990. First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990. Measurement Technologies. en_US
dc.identifier.uri http://hdl.handle.net/10524/47938
dc.language.iso en-US en_US
dc.publisher Measurement Technologies en_US
dc.relation.ispartofseries CN-137 en_US
dc.relation.ispartofseries Quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii en_US
dc.subject True/Mid-Pacific Geothermal Venture en_US
dc.subject True Geothermal Company Monitoring Program, Kilauea Middle East Rift Zone en_US
dc.subject Hawaii Island en_US
dc.subject meteorology en_US
dc.subject Kilauea East Rift Zone en_US
dc.subject Kilauea en_US
dc.subject Big Island en_US
dc.subject Puna en_US
dc.subject Hawaii en_US
dc.subject.lcsh Hydrogen sulfide--Environmental aspects--Hawaii--Puna en_US
dc.subject.lcsh Geothermal power plants--Environmental aspects--Hawaii--Puna Region en_US
dc.subject.lcsh Geothermal resources--Environmental aspects--Hawaii--Puna Region en_US
dc.subject.lcsh Air quality--Hawaii en_US
dc.title First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990 en_US
dc.type Report en_US
dc.type.dcmi Text en_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1990 - Quality Assurance Report - KMERZ - 1st Quarter.pdf
Size:
8.38 MB
Format:
Adobe Portable Document Format
Description: