WRRCSR No.12:28:84 Brackish Groundwater Desalting Tests Using Low Pressure Reverse Osmosis Membranes, Wai'anae, O'ahu, Hawai'i

Date
1984-12
Authors
Gee, Henry K.
Lau, L. Stephen
Contributor
Advisor
Department
Instructor
Depositor
Speaker
Researcher
Consultant
Interviewer
Annotator
Journal Title
Journal ISSN
Volume Title
Publisher
Water Resources Research Center, University of Hawaii at Manoa
Volume
Number/Issue
Starting Page
Ending Page
Alternative Title
Abstract
A desalting test using low pressure, reverse osmosis (RO) FT-30 and FT-50 membranes was conducted on Pump 10 well water at Oahu Sugar Company near Campbell Industrial Park on O'ahu. The brackish test water from the Waianae basalt aquifer had a chloride (Cl-) concentration of 450 mg/l and a total dissolved solids (TDS) concentration of 1250 mg/l. The applied pressure ranged from 40 to 75 psi with a daily incrementof 5 psi. The test operation duration was 239 hr. The FT-30 membrane demonstrated high rejection of Cl-, TDS, and silica (>90%), thus producing an excellent potable water. The permeate water production was slow, averaging 10.3 gpd or 4.6% of the feedwater. The production rate increased with pressure. The fouling rate was slow and longer runs could be made before cleaning became necessary. The FT-50 membrane yielded high permeate production (approximately four times that of FT-30), but was of poor (sub-potable) water quality with average rejection of Cl- at 17% and TDS at 25%. The fouling rate of the membrane was high, seriously reducing the permeate production in a short time. Cleaning with dilute phosphoric acid followed by Wisk and NaOH solution restored about 45% of the production rate. A large-scale RO module (element) should be tested for a longer period of time to determine sustainable performance of fouling rate. After reaching 15% reduction in the permeate production rate, various cleaning agents should be tested to restore the rate and to determine the type of fouling. By using a full-size commercial element, uncertainties of scale-up from small laboratory units can be eliminated. A longer operating period using the available pump pressure would yield more meaningful design data than the short, 2-wk test period using laboratory-size elements.
Description
Keywords
Brackish waters., Groundwater -- Hawaii -- Oahu., Saline water conversion -- Reverse osmosis process., Waianae (Hawaii)
Citation
Gee HK, Lau LS. 1984. Brackish groundwater desalting tests using low pressure reverse osmosis membranes, Wai'anae, O'ahu, Hawai'i. Honolulu (HI): Water Resources Research Center, University of Hawaii at Manoa. WRRC special report, 12:28:84.
Extent
iv + 21 pages