Identification of Linear Power System Models Using Probing Signals

File Size Format  
0315.pdf 2.29 MB Adobe PDF View/Open

Item Summary

Title:Identification of Linear Power System Models Using Probing Signals
Authors:Cárdenas Javier, Romel Angel
Zelaya Arrazabal, Francisco Alexander
Arrieta Paternina, Mario Roberto
Wilches-Bernal, Felipe
Keywords:Monitoring, Control and Protection
system identification
linear model
loewner method
frequency interpolation
show 1 moresmall-signal analysis.
show less
Date Issued:05 Jan 2021
Abstract:This paper compares the accuracy of two methods to identify a linear representation of a power system: the traditional Eigensystem Realization Algorithm (ERA) and the Loewner Interpolation Method (LIM). ERA is based on time domain data obtained using exponential chirp probing signals and LIM system identification method is based on frequency domain data obtained using sinusoidal probing signals. The ERA and LIM methods are evaluated with the noise produced by the nonlinear characteristics of the system, these characteristics are caused by increasing the amplitude of the applied probing signal. The test systems used are: the two-area Kundur system and a reduced order representation of the Northeastern portion of the North American Eastern Interconnection. The results show that the LIM method provides a more accurate identification than the ERA method.
Pages/Duration:10 pages
URI:http://hdl.handle.net/10125/71006
ISBN:978-0-9981331-4-0
DOI:10.24251/HICSS.2021.391
Rights:Attribution-NonCommercial-NoDerivatives 4.0 International
https://creativecommons.org/licenses/by-nc-nd/4.0/
Appears in Collections: Monitoring, Control and Protection


Please email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.

This item is licensed under a Creative Commons License Creative Commons