First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990

Item Summary

Title: First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990
Authors: Measurement Technologies
Keywords: True Mid-Pacific
air quality
air sampling
emissions
hydrogen sulfide
show 7 moremeteorology
Kilauea Middle East Rift Zone
KMERZ
Kilauea
Big Island
Puna
Hawaii

show less
LC Subject Headings: Air quality--Hawaii
Issue Date: 1990
Publisher: Measurement Technologies
Citation: Measurement Technologies. 1990. First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990. Measurement Technologies.
Series/Report no.: CN-137
Quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii
Abstract: "The aerometric analyzer audit results were satisfactory. The sulfur dioxide (502) and hydrogen sulfide (H2S) analyzers meet the slope and intercept criteria. Although the H2S analyzer passed the slope and intercept criteria, the analyzer exhibited a large negative differential on the lower concentration range of the analyzer.
The analyzer linerizer was adjusted and a post audit was performed. The reaudit showed satisfactory results and the low range showed a smaller negative differential.
The meteorological equipment audit results were satisfactory.
The particulate sampler audit results were satisfactory.
All operational procedures followed at the monitoring sites were consistent with EPA guidelines, and all instrument/analyzer calibrations were done in a proper manner. All documentation was found to be complete, concise, and up to date."
Sponsor: True Geothermal Energy Company
Pages/Duration: 35 pages
URI/DOI: http://hdl.handle.net/10524/47938
Appears in Collections:The Geothermal Collection