Title: Concentrations of Non-Criteria Air Pollutants in the Vicinity of the Geysers, California
Authors: Altshuler, Samuel L.
Arcado, Theodore D.
Lin, Dr. Chin-I
Keywords: air quality
emissions
Geysers, CA
Issue Date: 1986
Publisher: Pacific Gas & Electric Company
Citation: Pacific Gas & Electric Company. 1986. Concentrations of Non-Criteria Air Pollutants in the Vicinity of the Geysers, California. San Ramon, California: Pacific Gas & Electric Company.
Abstract: Ambient air monitoring for non-criteria pollutants was conducted to assess the impact of geothermal steam utilization on the ambient air at The Geysers. The measurements revealed no exceeds of any ambient air quality standards, state, federal, or foreign. Except for mercury vapor, radon. and ammonia, all of the pollutants were measured at near detection limit concentrations using methds that are state-of-the-art. Mercury vapor seems to be more related to the known geologic cinnabar deposits and past mining operations in the area than to geothermal steam utilization at The Geysers.